Showing posts with label AN. Show all posts
Showing posts with label AN. Show all posts

Build an Ultrasonic Proximity Detector

[ REPORT ] Obstacle detection Robot with Ultrasonic Sensors

Build an Ultrasonic Proximity Detector

Whether you want to build an automatic flush toilet for your home or design a machine to taunt your cat every time she walks by, our friends from Nuts & Volts Magazine have this great ultra-simple, ultrasonic proximity detector. 


The circuit in Figure 1a and Figure 1b are the schematics of an ultrasonic proximity detector. It has a maximum detection range of approximately 6 ft. When someone passes in front of the ultrasonic transceiver board, the contacts of relay K1 will close. The relay will remain energized while the device continues to detect a reflection. When there is no reflection, the relay contacts will open after 20 seconds. Photo 1 shows the assembled circuit on an experimenter's breadboard. 


The circuit consists of the following:

40 kHz Ultrasonic Sensor Set (Transmitter)
(P/N 136654)
  • a. Crystal Oscillator
  • b. Drivers

  • 40 kHz Ultrasonic Sensor Set (Receiver)
    (P/N 139492)
  • a. 68 dB Amplifier
  • b. Cascade Voltage Doubler
  • c. Threshold Detector
  • d. 70 Hz Oscillator
  • e. One-Shot (Monostable Multivibrator)
  • f. Relay
  • Step1: Transmitter

    U2C forms a 40 KHz oscillator (figure 3 shows the 40 KHz crystal assembly). This oscillator is connected to U2D and U2E while the inverted oscillator signal (U2B) goes to U2A and U2F. These parallel gates provide more current and drive the ultrasonic transmitter. Note that it may take a couple of seconds after the power is applied for the oscillator to stabilize.

    Step 2: Receiver

    Q1 and Q2 amplify the reflected 40 KHz signal picked up by the ultrasonic receiver by 2500. Q2 is capacitively coupled to the voltage doubler formed by D1 and D2. The rectified signal is connected to the negative input of voltage comparator U1A. R12 (the Sensitivity potentiometer) sets the threshold voltage for U1A. When the threshold voltage is exceeded, the open collector output of U1A goes high-impedance. This enables the 70 Hz oscillator formed by U1B. When this oscillator is on, the LED glows and the one-shot formed by U3 is repeatedly triggered. The output duration of the one-shot is set by R16 and C11 and is equal to 1.1*R16*C11 seconds. U3's output turns on Q3. As a result, K1 closes its normally open contacts. C13 dampens the inductive kickback when K1 is turned off, preventing the circuit from triggering due to this noise source. The unit is powered by a 12 VDC 200mA unregulated wall transformer. U4 provides a regulated 9VDC to power the circuit. Device pinouts are shown in Figure 2. The 40 KHz transmitter and receiver are mounted 4 inches apart on a piece of perfboard.

    To calibrate the device, have someone stand at the desired detection distance in front of the transceiver board. Next, turn the Sensitivity Control (R12) until LED D3 glows. Then rotate R12 slightly in the opposite direction until the LED goes out. Noise may cause the device to trigger randomly, causing the LED to blink. If this happens, turn R12 slightly to reduce the circuit's sensitivity. One application for this circuit is turning on a door chime. Another use is detecting a person on a porch and turning on an exterior light. This can be accomplished by wiring the normally open contacts of the relay in parallel with the lamp SWITCH. Have fun with your Ultrasonic Proximity Detector. 
     
    if u like the post just say thank u in comment box.

    [ System Set up ]An android based monitoring and alarm system for patients with chronic obtrusive disease.

    Some Importantant links below with reports.just view the link below. if u want any project report just search any project on our search box
    Arduino interesting projects:   
    Arduino 30 simple and good projects 
    Atmega projects lists
    Android Electronics projects lists
    Rf based Projects with report
    engineering study notes 
    GSM GPS based projects with report
    Bluetooth based projects with reports
    System Set up
    The following chapter will go step by step through each part of the developed
    system, including hardware devices and software involved in the development
    process. Everything from the initial set up to the data collection stage is covered.

    3.1 Sensors

    Sensors as a hardware equipment is an essential part of any monitoring device.
    The total amount of sensors involved in a monitoring process can be increased,
    providing a more sophisticated level of the analysis and enchanting data processing.
    Possible suggestions are discussed in Chapter 4 and 6. It was decided,
    however, to use a limited amount of sensors in the current project and establish
    a reliable connection for subsequent data transferring.

    3.1.1 Accelerometer

    The accelerometer sensor is an important component of the developed system
    as well as any other system involving patients monitoring. It provides a basic information
    about daily activity of the person, which can be further modified and
    used as one of the parameters for the analysis. Before describing the accelerometer
    application and usage in this particular project we consider it sufficient to
    mention several features of this type of sensor.
    Conceptually, any accelerometer behaves as a damped mass on a spring.
    When the accelerometer experiences an acceleration, the mass is displaced to
    the point where the spring is able to accelerate the mass at the same rate as the
    casing. The displacement is then measured to give the acceleration.
    In commercial devices, piezoelectric, piezoresistive and capacitive components
    are commonly used to convert the mechanical motion into an electrical
    signal1. Piezoelectric accelerometers rely on piezoceramics (e.g. lead zirconate
    1Accelerometer, http://en.wikipedia.org/wiki/Accelerometer
    31



    Figure 3.1: Accelerometer axes
    titanate) or single crystals (e.g. quartz, tourmaline). These crystal structures become
    stressed by accelerative forces, which causes a voltage to be generated.
    Piezoresistive accelerometers are unmatched in terms of their upper frequency
    range, low packaged weight and high temperature range and preferred in high
    shock applications. Capacitive accelerometers typically use two silicon micromachined
    sensing elements. Having these two micro structures next to each
    other, creates a certain capacitance between them. If an accelerative force moves
    one of the structures, then the capacitance will change. Additionally, converting
    some circuitry from capacitance to voltage we will be able to get a full
    accelerometer 2. Performance of these type of sensors is superior in the low frequency
    range and they can be operated in servo mode to achieve high stability
    and linearity. Modern accelerometers are often based on small electromechanical
    devices (micro electro-mechanical systems or MEMS) and normally inbuilt
    in the latest generation of the smart phones (including the one involved in the
    project). In our case it can be reached by programming through the android
    operating system with the help of ”SensorManager“ class and special Sensor
    Activity. The simple pseudo code example is provided below:
    S e n s o rAc t i v i t y {
    g e t S e n s o r S e r v i c e ( ) ;
    g e tDe f aul t S ensor ( SensorType ) ;
    onResume ( ) {
    r e g i s t e r S e n s o r L i s t e n e r ( t h i s , Ac c e l e rome t e r ) ;
    }
    onPause ( ) {
    u n r e g i s t e r S e n s o r L i s t e n e r ( t h i s , Ac c e l e rome t e r ) ;
    2A beginner’s guide to accelerometers, http://www.dimensionengineering.com/accelerometers.htm
    3.1. SENSORS 33
    }
    onSensorChanged ( SensorEvent ) {
    Do something i f s ensor i s moved ;
    }
    }
    Once the sensor is activated there are several methods provided by the previously
    mentioned class which can be used in order to measure activity. It is
    represented by three variables x,y,z which output device acceleration along the
    raw, pitch and yaw direction[33] (see Figure 3.1). First of all, we need to make
    sure at least one sensor is available for the measuring process. A special method
    ”isSupported“ is used for this purpose:
    i sSuppor t ed ( ) {
    i f ( notSuppor ted ) {
    g e t S y s t emS e r v i c e ( s e n s o r S e r v i c e ) ;
    L i s t s ensor s = g e t S e n s o rLi s t ( ac c e l e rome t e rType ) ;
    suppor ted = new Boolean ( s e n s o r s S i z e ) ;
    } e l s e {
    do nothing i f s ensor i s suppor ted ;
    }
    }
    r e turn suppor ted ;
    }
    The next step is to invoke a special ”startListening“ process which registers
    a listener and starts listening to the accelerometer callback for possible events
    (shaking, changing position etc.). This method also includes a configuration
    component where we can decide on a threshold for the changes in accelerometer
    and interval between shakes. It can help to react only on significant changes
    and simplify data collection in the next stages.
    Now, any change/event, which arises while the accelerometer is in the ”listening
    mode” will be registered and processed. It is reasonable to introduce a
    threshold for eliminating insignificant changes in raw/pitch/yaw values of the
    accelerometer. All the values below this threshold will not be considered. We
    can furthermore use previously detected acceleration and display it on a screen
    or store it in a file for further processing. Both options are implemented in our
    case. Possible approaches for accelerometer data processing will be described
    in Chapter 4.

    3.1.2 Nonin Wrist 0x2

    The following section is dedicated to the technical specifications of the sensor
    device used in this project. Description is based on a ”Fingertip Oximeter
    Technology Specifications” document [1] and provides additional information
    concerning the current system features. The picture of the sensor is provided on




    All the technical specification and parameters of the Pulse Oximeter are
    combined into an appropriate table (see Figure ??). The most significant information
    in terms of the system development are Oxygen Saturation and Pulse
    Rate Accuracy.


    The table is followed by bluetooth configurations including Operating Frequency
    and Operating Range.
    Technically, Nonin Wrist 0x2 oximeter is a slave device. To connect sensor
    to a master device, the master device must first associate with the 3150 by inquiring
    for the 3150. For the initial pairing of a new host device (master) to
    the 3150, it is discoverable for a minimum of 2 minutes after power-on. During
    the discovery period, the 3150 will broadcast a friendly name to the master.
    The name starts with ”Nonin_Medical_Inc._”, followed by a 6-digit number,
    referred to as the PIN. The PIN is etched on the back of the 3150 enclosure.


    To complete the pairing process once the master (host) device finds the 3150,
    the PIN must be provided to the master device. Once paired, the master must
    establish the connection to the sensor.
    This particular model provides measurements in several different data formats:
    • Data format 13 – provides easy spot-check measurements with the storage
    and forwarding of measurements.
    • Data format 8 – provides real-time oximetry measurements every second.
    • Data format 2 – provides real-time oximetry measurements with compressed
    waveform (8 bit waveform) every 1/75 of a second.
    • Data format 7 – provides real-time oximetry measurements with full resolution
    waveform (16 bit waveform) every 1/75 of a second.
    For data formats 1, 2, 7 and 8, the 3150 will not initiate the connection using
    the attempt to reconnect (ATR) option. If the system has only one COM port
    available, data format 2, 7, 8, or 13 should be used with the ATR disabled. The
    master device must initiate the connection by occasionally polling for the 3150.
    For an automatic wireless reconnection, a software should be designed to periodically
    poll for the 3150. If polling for the 3150 is not possible, Bluetooth
    connection should be started manually. Because the manual method typically
    requires the user to initiate the Bluetooth connection, the seek/polling method
    has its advantages.
    The 3150 will be discoverable when not paired to an existing master. Any
    previous master devices should be off. Once the device pairs and establishes the
    Bluetooth connection with the 3150, sensor will automatically send continuous
    data to device as defined in Data Format Definition section later. For further details
    on establishing a Bluetooth wireless connection see Appendix A. A Bluetooth
    connection indicator becomes available on the screen, after pushing and
    holding a bluetooth button. Once the Bluetooth connection is established, the
    3150 receives and transmits data using the SPP protocol. Additionally, there are
    several settings and commands for data format and time information:
     (1) Setthe Data Format and Activation,
     (2) Set Multiple Parameters,
     (3) Set the Date and Time in the 3150,
     (4) Set Bluetooth Radio timeout (power saving feature),
    (5) Get the Date and Time from the 3150,
     (6) Get the Serial Number in the3150,
     (7) Get revision number.
    In each case user must send a preliminary byte command string in order to
    select Data format, set or retrieve time. A data format is a key information for
    receiving, displaying and processing the sensor measurements. Thus, it is important
    to mention several details on it’s structure. A default Serial Date Format 2
    (one of the listed above) was used in development. This data format provides
    continuous data transmission of a 5 byte data packet sent 75 times per second.
    The data packet includes real-time data of: 8-bit waveform value, beat-to-beat
    SpO2 value, SpO2 and Pulse Rates values formatted for both recording and
    display purposes, status of the measurement and battery. Each particular byte
    represents a valid information.
    Byte 1 – START BYTE:
    Always set to a 01 value.
    Byte 2 – STATUS BYTE:
    This byte provides status information at a rate of 1/75 of second.
    Range: 128 to 255
    Byte 3 – PLETH BYTE:
    This byte consists of an 8 bit plethsmographic waveform (pulse waveform).
    The pulse oximeter infra-red signal is filtered and then compressed into an 8 bit
    value. The compression provides good detail for low to large pulse signals. For
    uncompressed waveform refer to Data Format 7.
    Range: 00 to 255
    Byte 4 – FLOAT BYTE:
    This byte is used for SpO2, Pulse Rate, and information that can be processed
    at a rate of 1/3 of second.
    Range: 00 to 127
    When the device is removed from the finger the last SpO2 and Pulse Rate
    reading will be reported for 10 seconds before changing to the missing data
    value. During this 10 second period the sensor alarm bit (SNSA) is set, indicating
    that the finger has been removed. This feature is useful for spot-check
    measurements. When SpO2 and HR cannot be computed, the system will send
    a missing data indicator. For missing data, the HR equals 511 and the SpO2
    equals 127.

    Byte 5 – CHK:
    This byte is used for the checksum of bytes 1 through 4.
    A concrete information on the processing of the sensor measurements can be
    found in Chapter 4 of the thesis.

    3.2 Processing Device

    The current section will go through the second part of system hardware used for
    the developing purposes. Several main aspects concerning technical parameters
    and programming Android API (Application Programming interface) will be
    covered and formulated according to their involvement in the process.
    3.2.1 Samsung smart-phones
    All the information sent by sensors (excluding accelerometer, inbuilt in phone)
    can be received by processing device through Bluetooth connection. Both Samsung
    Galaxy S and Samsung Galaxy Tab used for the actual thesis work, have
    a Bluetooth functionality. Thus, next step would be to get an access to this feature
    through the programming language, which is in our case Java. No license
    or special agreement is required to program previously mentioned devices, both
    based on an Android operating system.
    Before proceeding to the next step, it is important to mention some general
    aspects about Bluetooth option. According to the both smart-phones manuals,
    Bluetooth is a short-range wireless communications technology capable of exchanging
    information over a distance of about 10 m without requiring a physical
    connection [36]. Furthermore, we do not need to line up the devices to beam
    information with Bluetooth. If devices are within the range of one another, any
    information exchange between them is possible even if they are located in different
    rooms. However, we should always ensure that sharing and receiving data
    is performed with devices that are trusted and properly secured. If there are obstacles
    between the devices, the operating distance may be reduced. Moreover,
    some devices, especially those that are not tested or approved by Bluetooth SIG
    3, may be incompatible with the involved device.
    Other than Bluetooth option, there are more technical parameters possessed
    by Samsung Galaxy S, making it sufficient enough to be involved in monitoring
    system and subsequent data analysis. The parameters within our scope are
    memory (capacity) and operating frequency. The Samsung Galaxy S has the
    S5PC110 processor. This processor combines a 45 nm 1 GHz ARM Cortex-
    A8 based CPU core with a PowerVR SGX 540 GPU made by Imagination
    Technologies which supports OpenGL ES 1.1/2.0 and is capable of up to 20
    3Special Interest Group, http://www.bluetooth.com/Pages/About-Us.aspx
    million triangles per second. The CPU core, code-named ”Hummingbird”, was
    co-developed by Samsung and Intrinsity.
    In terms of memory, the Samsung Galaxy S has 512 MB of dedicated LPDDR2
    RAM (Mobile DDR) and 16-32 MB of OneDRAM. Some variants also come
    with either 8GB or 16GB of OneNAND memory combined in a package-onpackage
    stack with the processor. An external microSD card slot supports up
    to 32GB of additional storage memory 4. Additionally, the smart-phones used
    for programming runs on Android 2.1 (a.k.a. ”Eclair”) operating system.

    3.2.2 Application development

    It was decided to use Eclipse programming environment for development as one
    of the most sufficient and user friendly. All the communications between processing
    device and sensors are implemented through the application interface.
    A special application was designed and successfully ran for this particular purpose.
    The first step and a one of the main goals of this program was to establish
    a reliable connection. Once connection is initialized and running, it is important
    to maintain a signal in order to provide consistent interaction. In other
    words, we want to continuously store all the data received from the sensor in
    the phone memory and any kind of interruption would negatively affect the
    quality of the future analysis. A special android project was created, based on
    the Eclipse software in order to use all the available classes of android development
    environment. A project consists of two main ”activities” and one special
    ”service” which is responsible for a consistent data transmission. We consider
    it important to highlight main parts of these programming components in the
    following description.
    Firstly, we want to ensure the Bluetooth option is available and enabled
    on the device before we start any kind of operations [27]. Two simple commands
    perform a system check for both previously mentioned cases and can be
    executed with the following pseudo code:
    / / check i f blue tooth i s suppor ted
    i f ( BluetoothAdapter ( notSuppor ted ) ) {
    pr intOut ( ’ ’ Blue tooth i s not a v a i l a b l e ’ ’ ) ;
    f i n i s h ( ) ;
    r e turn ;
    }
    and
    / / check i f blue tooth i s enabled
    i f ( BluetoothAdapter ( notEnabled ) ) {
    BluetoothAdapter = Act ionReques tEnable ;
    }
    The last command sends a request to enable bluetooth on the operating device
    in case this option is currently disabled. Once bluetooth function is switched on,
    4Samsung Galaxy, http://en.wikipedia.org/wiki/Samsung_Galaxy_S
    we can proceed to the next step. An advanced user interface was not among the
    highest priorities of this project, however, several options are available within
    the main application screen depicted below.
    It is important to store some basic patients personal information, which will
    be further used in data processing part. So, as it is shown on Figure 3.5, every
    user can type in and save his/her age and weight in the corresponding field.
    The number will be later written to a special file and ready to be extracted for
    processing.
    Figure 3.5: Application main screen
    Next option allows user to get an access to accelerometer sensor through
    the android API. This part was described more specifically in Section 3.1.1 of
    this thesis. A data storing procedure is performed again. This time a special
    file, representing accelerometer along three axis is created and updated continuously.
    Current numbers are displayed on a screen and match the values stored
    to the device memory. You can read more about data format in Section 3.2.3
    of the current chapter.
    After accelerometer is set up and running, we can proceed to the main part,
    where connection between a sensor and android phone needs to be established.
    A ”START APP” button will initiate a second main activity, which provides
    user with a list of paired devices and opportunity to search for new ones (see
    Figure 3.6).
    In order to create a connection between application and a remote device
    (sensor in our case), we must implement either server-side or client-side mechanisms,
    because one device must open a server socket and the other one must
    initiate the connection (using the server device’s MAC address to initiate a connection).
    The server and client are considered connected to each other when
    they each have a connected BluetoothSocket on the same RFCOMM channel.
    At this point, each device can obtain input and output streams and data trans40

    fer can begin. We are interested in client-side option.
    So, in order to initiate a connection with a sensor (a device holding an
    open server socket), we should first obtain a BluetoothDevice object that represents
    the remote device. After that we use the BluetoothDevice to acquire a
    BluetoothSocket and initiate the connection. This part of the mechanism is implemented
    in a ”BluetoothService” section of the program.
    After device is chosen and bluetooth connection service is running, application
    will automatically return to a main screen and we can now observe
    measurements below the ”Oximeter sensor” section on a display. A step by
    step tutorial on starting sensor readings is provided in a special manual (see
    Appendix A) written for the Backagården personnel.

    3.2.3 Data collection

    Once the system is set up properly and the main application has been started
    on the testing device, it is possible to start data collection for the subsequent
    analysis. Two possible categories of the data that can be processed are represented
    by two different scenarios. Firstly, we perform testing with the healthy
    person, who is unlikely to have any kind of abnormalities and moreover any
    kind of chronic diseases. A second data set is expected to come from preliminary
    selected patients, who agreed to participate in the experimental part of
    the current research. The experimental part is described in details further below
    forming Chapter 5 of the thesis. The process implies receiving, storing and
    analyzing the data extracted from the measuring devices. All the information is
    sent via Bluetooth channel establishing “mobile phone - sensor” communication.
    processing device. Each measurement is retrieved from a different source and
    represented by four separate files:
    • sensors.txt (pulse rate and oxymetry)
    • activity.txt (raw, pitch, yaw from accelerometer)
    • age.txt (user input)
    • weight.txt (user input)
    The first two files have a particular format and consist of three separate column
    vectors, including a special time vector.
    20110519T175925 82 96
    20110519T175927 82 97
    20110519T175929 82 96
    20110519T175931 82 96
    This information is intended to simplify and at the same moment significantly
    improve further analysis of the data. Having access to the time makes it easier
    to register every particular change and follow the input flow as it is shown on


    The entire concept of Chapter 3 was based on several goals announced in
    the introduction part of the thesis. Firstly, it was required to establish a reliable
    connection between sensor and processing device, which is impossible without
    considering key aspects of sensor technical specification such as data format
    and operating modes. Secondly, we provide general information on data collection
    procedure, which is summarized in Table 3.1 above. Moreover, Table 5.3

    T

    from Section 5.2 contains detailed information about data transfer, including
    data loss in percentage. These measurements are sent and retrieved in a particular
    format (see a cutout of measurements above), developed for this particular
    application. It was designed to cover all the details and provide user with an
    easy interface for a sensor - device communication. The very same application
    carries out a data collection procedure.

    Some Importantant links below with reports.just view the link below. if u want any project report just search any project on our search box
    Arduino interesting projects:   
    Arduino 30 simple and good projects 
    Atmega projects lists
    Android Electronics projects lists
    Rf based Projects with report
    engineering study notes 
    GSM GPS based projects with report
    Bluetooth based projects with reports

    if u like the post just say thank u in comment box.

    DEVELOPING AN EFFECTIVE NETWORK SECURITY POLICY

    DEVELOPING AN EFFECTIVE NETWORK SECURITY POLICY


    A study reported by the U.S. General Accounting Office (GAO) (1996) found that the U.S. Department of Defense network computers are extremely vulnerable. A series of security attacks conducted by the Defense Information System Agency (DISA) revealed that of 38,000 attacks DISA could penetrate the protection and gain access to the network computers 65% of time. Of those successful attacks only 4% (988 attacks) were detected by the target organization. Furthermore, of those detected, only 27% (267 attacks) were actually reported to the appropriate security authority. Given the sophisticated computer network at the Department of Defense and the number of computer personnel involved, the statistics are alarming. The goal of network security is to provide maximum security with minimum impact on the user accessibility and productivity. The network